Tips & Tricks no. 5 - How to calculate the correct total air quantity
As a rule the ideal powder velocity to is 10 - 15 m/s. To achieve this result you must calculate the total air. The two crucial factors in this are the values for:
- The internal diameter of the hose
- The velocity of the powder
For the sample calculation below we assume a powder velocity of 12 m/s and an internal hose diameter of 9 mm (r = 4.5 mm).
This is the formula:
|
 |
| |
| and here's the calculation: |
 |
In real terms this means that you must set a total air figure (feed and dosage air together) of 2.7m3/h. To make things a little easier for you we have already calculated the total air quantity for the most common internal hose diameters:
Internal hose Ø
|
Powder velocity
|
Total air
|
9 mm
|
12 m/sec
|
2.7 m3/h
|
10 mm
|
12 m/sec
|
3.4 m3/h
|
11 mm
|
12 m/sec
|
4.1 m3/h
|
12 mm
|
12 m/sec
|
4.9 m3/h
|