HomeContact UsLiquid Distributors CanadaTips & Tricks no. 5 - Calculating the total air quantity
Powder Distributors U.S.  Liquid Distributors U.S.  Powder Distributors Canada Liquid Distributors Canada Powder Distributors Mexico Liquid Distributors Mexico Sales U.S. Sales International Service U.S. Tips & Tricks no. 5 - How to calculate the correct total air quantity


As a rule the ideal powder velocity to is 10 - 15 m/s. To achieve this result you must calculate the total air. The two crucial factors in this are the values for:
  • The internal diameter of the hose
  • The velocity of the powder
For the sample calculation below we assume a powder velocity of 12 m/s and an internal hose diameter of 9 mm (r = 4.5 mm).


This is the formula:
 
and here's the calculation:


In real terms this means that you must set a total air figure (feed and dosage air together) of 2.7m3/h. To make things a little easier for you we have already calculated the total air quantity for the most common internal hose diameters:

Internal hose Ø
Powder velocity
Total air
9 mm
12 m/sec
2.7 m3/h
10 mm
12 m/sec
3.4 m3/h
11 mm
12 m/sec
4.1 m3/h
12 mm
12 m/sec
4.9 m3/h

Learn how to set the total air in the next issue of our Tips & Tricks.